Dimensions without packaging (H x W x D) [mm(in.)] | Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.66 in.)
Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.4 in. x 8.94 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] | 90.0 mm x 550.0 mm x 360.0 mm (3.54 in. x 21.65 in. x 14.17 in.) |
Chassis height [U] | 1 U |
Chassis material | Metal |
Weight without packaging [kg(lb)] | 2.92 kg (6.44 lb) |
Weight with packaging [kg(lb)] | 3.79 kg (8.36 lb) |
Typical power consumption [W] | 40.07 W |
Typical heat dissipation [BTU/hour] | 136.72 BTU/hour |
Maximum power consumption [W] |
|
Maximum heat dissipation [BTU/hour] |
|
Static power consumption [W] | 30.82 W |
MTBF [years] | 60.18 years |
MTTR [hours] | 2 hours |
Availability | > 0.99999 |
Noise at normal temperature (acoustic power) [dB(A)] | 49.3 dB(A) |
Noise at normal temperature (acoustic pressure) [dB(A)] | 37.3 dB(A) |
Number of card slots | 0 |
Number of power slots | 0 |
Number of fans modules | 2 |
Switching capacity | To obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel. |
Packet forwarding rate | To obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel. |
Uplink ports | 4 x GE SFP ports |
Downlink ports | 24 x 10/100/1000BASE-T ports (400 W, PoE+) |
Redundant power supply | Not supported |
Long-term operating temperature [°C(°F)] | -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.) |
Restriction on the operating temperature variation rate [°C(°F)] | When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).
Devices cannot start when the temperature is lower than 0°C (32°F). |
Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158°F) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH (non-condensing) |
Long-term operating altitude [m(ft.)] | 0–5000 m (0–16404 ft.) |
Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Power supply mode | AC built-in |
Rated input voltage [V] |
|
Input voltage range [V] |
|
Maximum input current [A] | 6 A |
Memory | 2 GB |
Flash memory | Physical space: 1 GB |
Console port | RJ45 |
Eth Management port | Not supported |
USB | Not supported |
RTC | Not supported |
RPS input | Not supported |
Service port surge protection [kV] | Common mode: ±7 kV |
Power supply surge protection [kV] | Differential mode: ±6 kV; common mode: ±6 kV |
Ingress protection level (dustproof/waterproof) | IP20 |
Types of fans | Built-in |
Heat dissipation mode | Air cooling for heat dissipation, intelligent fan speed adjustment |
Airflow direction | Air intake from left and front, air exhaustion from right |
PoE | Supported |
Certification | EMC certification
Safety certification Manufacturing certification |
Huawei eKitEngine AP362 is a Wi-Fi 6 (802.11ax) wall plate access point (AP). It can simultaneously provide services on 2.4 GHz (2x2 MIMO) and 5 GHz (2x2 MIMO) frequency bands, achieving a device rate of up to 2.975 Gbps
]]>Integrated fixed device | Y |
First supported version | V200R021C11 |
Installation Type | Wall,Ceiling,T-Rail |
Dimensions without packaging (H x W x D) [mm(in.)] | Diameter x depth: 180 mm x 35 mm (7.09 in. x 1.38 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] | 52 mm x 231 mm x 200 mm (2.05 in. x 9.09 in. x 7.87 in.) |
Weight without packaging [kg(lb)] | 0.46 kg (1.01 lb) |
Weight with packaging [kg(lb)] | 0.80 kg (1.76 lb) |
CPU | 2-core, 1.0 GHz |
Memory | DDR3L 512 MB |
Storage | NAND Flash 256 MB |
Console port | None |
Maximum power consumption [W] | 11.2 |
Power supply mode | DC adapter,PoE |
Rated input voltage [V] | 12 V |
Input voltage range [V] | DC: 12 V ± 10% PoE: 802.3af |
Service port surge protection [kV] | PoE port: Common mode (8 wires to ground): 4 kV (1.2/50 us, 42 ohms), criterion C |
Maximum number of physical ports on the entire device | GE (RJ45) x 1, 10M/100M/1000M auto-sensing |
Long-term operating temperature [°C(°F)] | –10°C to +50°C (14°F to 122°F) (If the altitude is in the range of 1800 m to 5000 m, the temperature decreases by 1°C or 1.8°F every time the altitude increases by 300 m.) |
Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158°F) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH |
Long-term operating altitude [m(ft.)] | –60 m to +5000 m (–196.85 ft to +16404.20 ft) |
Atmospheric pressure [kPa] | 53kPa – 106kPa ETSI 300 019-2-3 |
Ground | floating ground |
BLE | Not supported |
Radio number | 2 |
Operating frequency band | 2.4GHz,5GHz |
MIMO spatial streams | Radio 0 (2.4 GHz): 2×2 Radio 1 (5 GHz): 2×2 |
Wi-Fi standard | 2.4G: 802.11b/g/n/ax 5G: 802.11a/n/ac/ac Wave 2/ax |
Radio interface | Built-in smart antennas |
Antenna gain | 2.4G: 4 dBi/chain (peak) 2 dBi (combined gain) 5G: 5 dBi/chain (peak value) 3 dBi (combined gain) |
Maximum transmit power | 2.4G: 20 dBm/chain 23 dBm (combined power) 5G: 20 dBm/chain 23 dBm (combined power) |
3G/LTE filte (ACC) | Not supported |
MTBF [year] | 205.07 |
MTTR [hour] | 0.5 |
Frequency stability [ppm] | +/-20 |
802.3bt power supply description | No function is limited. |
802.3at power supply description | No function is limited. |
802.3af power supply description | No function is limited. |
DC power supply description | No function is limited. |